Método de regresión polinomial aplicado a la estimación de la señal de referencia de un sistema de filtrado adaptativo por cancelación para el tratamiento del desplazamiento de la línea de base del electrocardiograma

Authors

  • Javier E. González Barajas Universidad Antonio Nariño

Keywords:

Sign of reference, electrocardiogram, polynominal regression, cancellation, leaked adaptive

Abstract

The systems of leaked (filtered) adaptative consist principally of a sign of reference. From these two series of time, the system of leaked adaptative conditions his internal variables to obtain the wished response. In the specific case of a system of leaked adaptative for cancellation, there is needed the estimation of mathematical function that shapes the distortion that wants to avoid of the sign of entry. This article centres on the problem of removal of the displacement of the base line of the electrocardiogram (ECG) for which a system has been designed for the estimation of the sign of reference, by means of the method of polynominal regression, whisch takes different points of the electrocardiogram. The sign of estimated reference is applied to a system of leaked adaptative by cancellation for the base line of the ECCG.

Downloads

Download data is not yet available.

References

J. BOTER, A. Den Hertog, and J. Kuiper. Disturbance free skin electrodes for persons during exercise. Med and Biol Eng And Comput Vol 4. (1996). pp 91.

H.W. Tam, and JG Webster. Minimizing electrode motion artifact by skin abrasion. IEE Trans. Biomed, Eng. Vol. 24 (1997). pp 134.

KOELEMAN, A.S.M., ROS, H.H. Ros & VAN DER AKKER, T.J. Van der Akker. Beat to Beat Interval Measurement in the electrocardiogram. Med & Biological Engineering & Computing. Vol. 23. (1985). pp 231.

TOMPKINS, Wills J. Biomédical Digital Signal Processing. Prentice Hall: USA. (1993). pp 100-116.

DOUGLAS, S. C. Introduction to Adaptive Filters. Digital Signal Processing Handbook. Ed. Vijay Madisetti and Douglas B. Williams. Boca Ratón. CRC Press LLC. (1999). Chapter 18 and 19.

BERTRÁN N, Madan y G, Peter N. A. “Baseline Tracking Algorithm for Drift Reduction in Electrocardiography”. IEEE Engineering in Medicine and Biology Society 10th Annual International Conference. (1988). CH2566-8/88/0000—1230. IEEE.

EZENWA B, GUPTA M, Nikforuk p, Prasad K. “A Baseline Algorthm for Drift Reduction in electrocardiography”. IEEE. Engineering in Medicine & Biology Society 10th Annuak International Conference. Signal Proccessing and Análisis: Poster Session II. (1988). CH2566-8-/88/000—1230. IEEE.

MOHAMMED F, Barr R. “Adaptive Digital Notch Filter Design on the Circle for the Removal of Powerline Noise from biomedical signals”. IEEE Transactions on Biomedical Engineering. (1994). Vol 41, No 6.

FARHANG B, Boroujeny. Adaptive filters theory and applications. John Wiley & Sons. (199). pp. 71-81.

CHAPRA S, CANALE R. Métodos Numéricos para Ingenieros. Mc Graw-Hill:. México. (1998).

Published

2012-10-25
Metrics
Views/Downloads
  • Abstract
    177
  • PDF (Español (España))
    64

How to Cite

González Barajas, J. E. (2012). Método de regresión polinomial aplicado a la estimación de la señal de referencia de un sistema de filtrado adaptativo por cancelación para el tratamiento del desplazamiento de la línea de base del electrocardiograma. INGE@UAN - TENDENCIAS EN LA INGENIERÍA, 1(1). Retrieved from https://revistas.uan.edu.co/index.php/ingeuan/article/view/419

Issue

Section

Artículo de investigación científica y tecnológica

Metrics